TH3
www.vishay.com
TYPICAL LEAKAGE CURRENT FACTOR
100
+ 125 °C
Vishay Sprague
10
+ 150 °C
+ 85 °C
+ 55 °C
+ 25 °C
1.0
0 °C
0.1
- 55 °C
0.01
0.001
0
10
20
30
40
50
60
70
80
90
100
Percent of Rated Voltage
Note
? At + 25 °C , the leakage current shall not exceed the value listed in the Standard Ratings table.
At + 85 °C , the leakage current shall not exceed 10 times the value listed in the Standard Ratings table.
At + 125 °C , the leakage current shall not exceed 12 times the value listed in the Standard Ratings table.
At + 150 °C , the leakage current shall not exceed 15 times the value listed in the Standard Ratings table.
RECOMMENDED VOLTAGE DERATING GUIDELINES (for temperatures below + 85 °C)
STANDARD CONDITIONS. FOR EXAMPLE: OUTPUT FILTERS
Capacitor Voltage Rating
6.3
10
16
20
25
35
50
SEVERE CONDITIONS. FOR EXAMPLE: INPUT FILTERS
Capacitor Voltage Rating
6.3
10
16
20
25
35
50
Operating Voltage
3.6
6.0
10
12
15
24
28
Operating Voltage
3.3
5.0
8.0
10
12
15
24
Revision: 03-Dec-13